7.2 TROUBLE SHOOTING


7-5
7
7.2 TROUBLE SHOOTING
As this radar equipment includes complicated circuits, it is necessary to request a specialist engineer for repair
or instructions for remedy if any circuit is defective.
There are also troubles by the following causes, which should be referred to in checking or repair work.
1 Poor Contact in Terminal Board of Inter-Unit Cables
a) Poor contact in terminal board
b) The cable end is not fully connected, that it, contacted with earthed another terminal.
c) Disconnected cable wire
2 Poor Contact of Connector within Unit
Reference: This radar equipment is provided with standard spares which include two kinds of fuses. Refer
to table 7-4.
Table 7-4 Spare Fuses ( for NCM-994)
Name
Type/Code
Shape (mm)
In use
Spare
Parts No.
Location
Fuse
ST4-5AN1
(5ZFCA00050)
1
3
F401
Inside processing
unit
Fuse
ST6-10AN1
(5ZFCA00053)
1
3
F402
Inside processing
unit
Table 7-5 Special Parts ( for NKE-387 )
Parts No.
Name
Type
Manufacturer
Location
Code
V101
Magnetron
MAF1562R
New JRC
Scanner
5VMAA00116
A101 / A102
Circulator
FCX68R
Orient
Microwave
Scanner
5AJIX00027
A103
Termination
NJC4002
New JRC
Scanner
5ANDF00001
A104
Spurious Filter
NJC9952
New JRC
Scanner
5AWAX00002
A301
Diode Limiter
NJS6930
New JRC
Scanner
5ATBT00006
31.8
Φ6.35
31.8
Φ6.35