EasyManua.ls Logo

JUKI HZL-X Series - Adjustment; 6-1 Adjusting the needle bar height

JUKI HZL-X Series
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 13 –
[6] Adjustment
6-1 Adjusting the needle bar height
Remove the face cover.
Adjustmentvalue:
Distancefromthebottomendofthepininsideneedlebarsurfacetothetopsurfaceofthethroatplate:
19 mm
Whentheneedleismounted,theneedleeyetiltsrightwardby2degrees.
Adjustmentprocedure1.
1.Selectthestraightstitchusingthepatternselectingbutton.Choosecenterneedleposition.
2.MakeagaugeneedlebycuttingahouseholdneedleHA×1todimensionA.Fitthegaugeneedleintothe
needlebar.
3. Prepare an appropriate metal plate of thickness B. (A = 19 mm - B)
4.Bringtheneedlebartoitslowestdeadpoint.Slightlyloosenneedlebarconnectingstudsetscrew
1
as
long as the needle does not slip off from the connecting stud.
5.Placethemetalplateonthethroatplate.Movetheneedlebarupanddownbyhandtoadjustsothatthe
cutsurfaceofthegaugeneedlealignswiththetopsurfaceofthemetalplate.Then,turntheneedlebarby
twodegreesofanangleasillustratedinthesketchbelow.
6.Temporarilytightenneedlebarconnectingstudsetscrew
1
andreconrmthattheneedlebariscorrectly
adjusted.Then,securelytightenthesetscrew.
Adjustmentprocedure2.
1.AssembleahouseholdHA×1needle#14intotheneedlebar,bringtheneedlebartoitshighestdead
point.Movetheneedlebarinthesamewayasdescribedinprocedure1toadjusttheneedlebarheightso
that the needle tip is spaced 15.5 mm from the top surface of the throat plate.
19 mm
Metal plate
Throat plate
[Lowest dead point]
A
B
Gauge needle
15.5 mm
[Highest dead point]
HA×1 #14
1