KE2000 Installation Manual
18
6-2. Detaching the head unit fixing parts
6-2-1. Detaching the MNLA head Z-axis fixing parts
1) Remove the SEMS cap screws (SL6030642TN) to detach the Z-axis stopper
(E3007729000).
2) Make sure that the Z-axis slide bracket moves smoothly in the vertical direction.
WARNING
WARNINGWARNING
WARNING
To prevent the body from injury which can be caused by
accidental activation of the machine , cut off the power to
the machine before starting to work.
Fig 6-2-1-1
SEMS cap x 2
(
SL6030642TN
)
Set-up caution tag
Z-axis stopper
(E3007729000)
Z-axis slide bracket