Adjustment Procedures Results of Improper Adjustment
1) Loosen the setscrew of upper looper ball arm 3 and setscrew
5 of the upper looper holder.
2) Adjust the clearances between upper looper bracket 4 and
upper looper holder 1 to approximately 0.2 mm respectively,
and tighten setscrew 5 of the upper looper holder.
(Make sure that the upper looper holder smoothly moves
together with upper looper shaft 6.)
3) Then determine dimension F from the bottom surface of the
frame to the top surface of upper looper holder pin 2 before
tightening the setscrew of upper looper ball arm 3.
(Caution) Replace upper looper holder 1 according to the
needle gauge size.
Inaccurately positioned upper
looper holder will cause
excessive projection of the
upper looper, resulting in stitch
skipping, or other troubles.
(Caution) To adjust the upper
looper ball arm, take
dimension F as standard.
Remember that the projecting
amount and the height of the
upper looper should
eventually be properly
adjusted. So, confirm the
dimensions related to the
upper looper.