−40
Standard Adjustment
(25) Position of the upper looper lubricating pin
1) Orientation of the lubricating pin
Oil inlet 2 of upper looper lubricating pin 1 should face upward.
2) Setting the lubricating pin
The clearance provided between upper looper lubricating pin 1 and upper looper bracket 4 should
be 0.15 mm.
0.15 mm clearance