−29 −
#2
Function of stop immediately after the reverse feed stitching at the start of sewing (Function setting No. 60)
This function temporarily stops the sewing machine even when keeping depressing the front part of the
pedal at the time of completion of process of reverse feed stitching at the start of sewing.
It is used when sewing a short length by reverse feed stitching at the start of sewing.
0 : Not provided with the function of
temporary stop of the sewing
machine immediately after the
reverse feed stitching at the start of
sewing
1 :Provided with the function of
temporary stop of the sewing
machine immediately after the
reverse feed stitching at the start of
sewing
Stop the sewing machine
temporarily to change direction
of sewing products.
#1 Change-over function of AUTO / Pedal for sewing speed of the reverse feed stitching at the start of
sewing (Function setting No. 59)
This function selects whether the reverse feed stitching at the start of sewing is performed without a break at
the speed set by the function setting No. 8 or the stitching is performed at the speed by the pedal operation.
0 : Manu The speed is indicated by the pedal operation.
1 : Auto Automatic stitching at the specified speed
(Caution) 1. The max. sewing speed of the reverse feed stitching at the start of sewing is limited to
the speed set by the function setting No. 8 regardless of the pedal.
2. When “0” is selected, stitches of reverse feed stitching may not match those of normal
feed stitching.
#0 Function of holding predetermined upper / lower position of the needle bar (Function setting No. 58)
When the needle bar is in the upper position or in the lower position, this function holds the needle bar by
applying a brake slightly.
0 : off Function of holding predetermined upper/lower position of the needle
bar is ineffective.
1 : on Function of holding predetermined upper/lower position of the needle
bar is effective.
2 : on Function of holding predetermined upper/lower position of the needle
bar is ineffective.
3 : on Function of holding predetermined upper/lower position of the needle
bar is effective.
#3 Bobbin thread remaining amount detection air blow output time (Function setting No. 61)
Air blow output time is set when bobbin thread remaining amount detection device is used.
Setting range 0 to 2000 [mS]
61
500
#4 Tie stitch adjustment function (Function setting No. 63)
Temporary stop time can be set at the respective corners of start, end and overlapped stitching at the time
of setting reverse feed stitching and overlapped stitching.
0 : Invalid
Setting range 0 to 1000 [mS]
63
10
Temporary stop is performed only for
the time set at this point.
58
0
59
1
60
0