−16
(10) Position of the needle bar connection guide
Standard Adjustment
(11) Height of the needle bar
Standard Adjustment
Conditions : Zigzag width : “0”
Position of needle position changing lever : Center
Part No. of engraved indication E
: 22536502
Dimension a: 12.2 mm
Dimension b: 3.4 mm
Woodruff
plate
Engraved
indication
Timing gauge
Needle bar
support base
Needle bar
connection guide
Needle bar crank
rod guide
1
2
3
4
5
1
a
b

Table of Contents