29
7 Technical data
7 Technical d ata
7.1 Control ranges and probe table
For TR, TW, TB – liquid-filled
For TR, TW, TB – gas-filled
Control
range/limit
value range
Switch-
ing differ-
ential
Max. probe
temperature
Max. switch-
ing head
temperature
Max. capillary
length
Max.
sequence
contact gap
Probe length "L",
probe Ø "d"
in mm
°C % °C °C in mm K Ø 6 (Standard) Ø 8
-20to+40 1
2.5
5
7
50
50
95
100
50 5000 5
8
25
50
245
245
138
103
145
145
91
73
0 to 50 1
2.5
5
7
60
60
105
110
60 5
10
25
50
283
283
159
117
165
165
101
80
20 to 90 1
2.5
5
7
115
115
140
175
80 7
14
35
70
210
210
121
91
127
127
82
67
0to100 1
2.5
5
7
125
125
165
200
80 10
20
50
100
157
157
94
73
100
100
68
58
30 to 110 1
2.5
5
7
135
135
170
200
80 8
16
40
80
188
188
110
84
116
116
76
63
0to150 1
2.5
5
173
173
200
80 15
30
75
113
113
72
78
78
57
0to200 1
2.5
230
230
80 20
40
113 78
50 to 200 1
2.5
230
230
80 15
30
139 92
50 to 250 1
2.
5
5
28
8
288
300
80 20
40
100
105
105
64
70
70
49
50 to 300 1
2.5
345
345
80 25
50
87 61
Control
range/limit
value range
Switch-
ing differ-
ential
Max. probe
temperature
Max. switch-
ing head
temperature
Max. capillary
length
Max.
sequence
contact gap
Probe length "L",
probe Ø "d"
in mm
°C % °C °C in mm K Ø 6 (Standard) Ø 8
20 to 400 5
10
460
500
80 5000 75
200
237
127
137
81
20 to 500 3/5
6
10
575 80 1000
5000
5000
48
95
250
278
276
95
158
106
65