Page #23 background image
JUNCTEK
18
turn off, and the screen will immediately turn on once there is current.
10).Bluetooth pairing password
The Bluetooth pairing password is 0000 by default. The Bluetooth pairing
password can only be modified through the display screen, and the mobile
APP cannot be modified. After the instrument is powered off and restarted, the
Bluetooth pairing password will return to the default value: 0000.
Press the keys to switch to the Bluetooth pairing password setting,
press the OK key to select the value, press the keys to change
the value, and press the
OK
key again to confirm the Bluetooth pairing
password.
11).Data record: On/Off (default is On)
In the system settings, press the keys to switch to the data record
switch. Press the
OK
key to select the On/Off/Clear mode, and then press
the
keys to switch. After selecting, press the
OK
key to confirm.
When selecting the Clear mode, the data record frequency can be set, which is
set to once per second by default.
12).Delay protection setting: 0-99s
In the system settings interface, press the
keys to switch to the delay
protection time setting. Short press the
OK
key to select the value with the
cursor, and press the
keys to change the value. Press the
OK
key again to confirm the set protection delay time.
When the delay time is set to 00s, the instrument will immediately enter
protection mode as the measured value exceeds the set protection value. If
the delay time is greater than 00s, for example, as the delay time is set to 5s,
the instrument will enter protection mode immediately as the measured value
exceeds the set protection value for 5s continuously.
The protection function requires the purchase of a separate relay. If a
relay is not equipped, do not set this value, and install a relay in the
circuit before it can act as a protective device to disconnect the circuit.
13).Zero current memory: Confirm
In the system settings interface, press the
buttons to switch to the
zero current memory setting. After a short press of the
OK
button, a pop-up
window for zero current memory will appear. Use the
】【
buttons to
select whether to confirm or cancel the zero current memory. When the cursor
is on the "Confirm" option, press the
OK
button. If the display shows
"Success," the storage of the state where the current is 0 at the zero point is
completed.
14).Relay mode: Normally open/Normally closed
In the system settings interface, press the
keys to switch to the relay
mode setting. Short press the
OK
key to select normally open or normally
closed with the cursor. Use the
keys to switch, and press the
OK
key again to confirm the relay mode. When using this function, select normally

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUNCTEK KH-F Series and is the answer not in the manual?

JUNCTEK KH-F Series Specifications

General IconGeneral
BrandJUNCTEK
ModelKH-F Series
CategoryMonitor
LanguageEnglish