JUNCTEK
open or normally closed based on the actual relay mode connected.
15).Address matching
In the system settings interface, press the 【▲】【▼】keys to switch to the
address matching setting. Short press the 【OK】key to select the value with
the cursor. Use the 【▲】【▼】keys to switch the communication address, and
press the 【OK】key again to confirm the communication address between the
display module and the measurement module. The communication address is
set to P01 by default.
When multiple measurement modules are connected, switching the current
communication address can control the corresponding measurement module.
16).Low battery warning: 0-100%
In the system settings interface, press the 【▲】 and 【▼】 buttons to switch
to the low capacity reminder setting. Short press the【OK】button to select the
value with the cursor, use the
【
▲
】
and
【
▼
】
buttons to change the value,
and press the 【OK】 button to confirm the set low capacity reminder. If the
current capacity is lower than the set low capacity, a warning sound will be
appeared and a pop-up reminder will last for 5 seconds.
(3). System Settings-Page 3:
Figure 3-1-3 System Settings - Page 3
17).Overvoltage protection: 0.00-120.00V
In the system setting interface, press the 【▲】【▼】 buttons to switch to
overvoltage protection setting. Press the 【OK】 button to select the value, use
the
【
▲
】【
▼
】
buttons to change the value, press the
【
OK
】
button to switch
the digit, and switch from the smallest digit to the highest digit. Press the【OK】
button again when in the highest digit to confirm the set overvoltage protection
value.
If the value is 000.00V, the protection function is not activated. If the value is
greater than 000.00V, the protection function will be activated. If the current
voltage is greater than the set overvoltage protection value, the screen will
display OVP in the upper left corner, indicating that the protection function is
activated.
The protection function requires the purchase of a relay. If there is no
relay, do not set the value. Install the relay in the circuit to disconnect the