EasyManuals Logo

JUNCTEK KH-F Series User Manual

JUNCTEK KH-F Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
JUNCTEK
19
open or normally closed based on the actual relay mode connected.
15).Address matching
In the system settings interface, press the keys to switch to the
address matching setting. Short press the OKkey to select the value with
the cursor. Use the keys to switch the communication address, and
press the OKkey again to confirm the communication address between the
display module and the measurement module. The communication address is
set to P01 by default.
When multiple measurement modules are connected, switching the current
communication address can control the corresponding measurement module.
16).Low battery warning: 0-100%
In the system settings interface, press the and buttons to switch
to the low capacity reminder setting. Short press theOKbutton to select the
value with the cursor, use the
and
buttons to change the value,
and press the OK button to confirm the set low capacity reminder. If the
current capacity is lower than the set low capacity, a warning sound will be
appeared and a pop-up reminder will last for 5 seconds.
(3). System Settings-Page 3:
Figure 3-1-3 System Settings - Page 3
17).Overvoltage protection: 0.00-120.00V
In the system setting interface, press the buttons to switch to
overvoltage protection setting. Press the OK button to select the value, use
the
buttons to change the value, press the
OK
button to switch
the digit, and switch from the smallest digit to the highest digit. Press theOK
button again when in the highest digit to confirm the set overvoltage protection
value.
If the value is 000.00V, the protection function is not activated. If the value is
greater than 000.00V, the protection function will be activated. If the current
voltage is greater than the set overvoltage protection value, the screen will
display OVP in the upper left corner, indicating that the protection function is
activated.
The protection function requires the purchase of a relay. If there is no
relay, do not set the value. Install the relay in the circuit to disconnect the