(3). R command
1 represents the communication
address;
177 represents the checksum;
The first 4 in 4140 represents the KH
series, 1 represents 120V, and 40
represents 400A;
116 represents version 1.16;
0 represents the machine serial
number.
1 represents the communication
address;
123 represents the checksum;
1198 represents the voltage at
11.98V;
1090 represents the current at
10.90A;
7421 represents the remaining
battery capacity at 7.421Ah;
2749 represents the discharge
electricity consumption at
2.749KWh;
437 represents the charging
electricity consumption at
0.437KWh;
298 represents the operational
record value at 298;
113 represents the environmental
temperature at 13ā;
0 represents a function to be
determined;
0 represents the output status as
ON; (0-ON, 1-OVP, 2-OCP, 3-LVP,
4-NCP, 5-OPP, 6-OTP, 99-OFF)
1 represents the current direction,
currently charging current;
(0-discharge, 1-charging)
69 represents the remaining time at
69 minutes;
100 represents the time adjustment
(to be determined);
230208 represents the date as