3.2 Liquid gas tank
Refillable liquid gas tanks contain a dispensing valve (66), a filling stop valve (64), a
relief valve (65) and a display (62).
Filling refillable liquid gas tanks (optional
equipment).
Requirements
Note all guidelines and regulations
concerning the filling of LPG bottles on the
LPG pump.
Procedure
Close the dispensing valve (66).
Unscrew the cap (63) of the filling stop valve
(64).
Screw the filling connection of the liquid gas
pump onto the filling stop valve (64).
Z Fuelling automatically ends when the tank's
capacity has been reached.
After fuelling, unscrew the filling connection and screw the cap (63) of the filling
stop valve (64) back on.
66
64
63
65
62