Create a new management VLAN. Specify the VLAN name, VLAN ID, management IP address, and default gateway.
Select the ports that must be part of this VLAN.
•
In out-of-band management, you use a dedicated management channel (MGMT port) to connect to the management
device. Specify the IP address and gateway of the management interface. Use this IP address to connect to the
switch.
14. (Optional) Specify the SNMP read community, location, and contact to configure SNMP parameters.
15. (Optional) Specify the system date and time. Select the time zone from the list. The configured parameters are displayed.
16. Enter yes to commit the configuration. The configuration is committed as the active configuration for the switch.
You can now log in by using the CLI and continue configuring the switch.
Guidelines for Using EX4650 RMA Replacement Chassis
The RMA replacement chassis for EX4650 is a universal chassis that comes installed with QFX5120 personality, and
preloaded with Junos OS for EX Series software image in the /var/tmp directory. You must change the personality of the
device to EX4650 beore performing the initial configuration. Use the console port to connect to the switch to change the
personality of the switch.
•
Log in as root. There is no password.
login: root
•
Install the EX4650 software package.
root# request system software add /var/tmp/jinstall-host-ex-4e-flex-x86-64-18.3R1.11-secure-signed.tgz force-host
reboot
•
Verify if the device is changed to EX4650 personality.
root> show version
•
Delete the EX Series software image from the /var/tmp directory if required.