EasyManuals Logo

JVC KD-Lh401 User Manual

JVC KD-Lh401
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
21
ENGLISH
2 Press number button 4 to select “TUNER”—
Tuner category of the PSM settings.
3 Press ¢ or 4 to select “TA Volume.
4 Turn the control dial to set to the desired
volume.
You can set it from “Volume 0” to “Volume 30”
or “Volume 50” (depending on the amplifier
gain control setting: see page 49).
5 Press SEL (select) to finish the setting.
Automatic clock adjustment
When shipped from the factory, the clock built in
this unit is set to be readjusted automatically
using the CT (Clock Time) data in the RDS
signal.
If you do not want to use automatic clock
adjustment, follow the procedure below.
See also “Changing the general settings
(PSM)” on page 45.
1 Press and hold SEL (select) for more than
2 seconds so that one of the PSM items
appears on the display.
2 Press number button 2 to select “CLOCK”—
Clock category of the PSM settings.
3 Press ¢ or 4 to select “Auto Adj”
(adjustment).
4 Turn the control dial counterclockwise to select
“Off.
Now automatic clock adjustment is canceled.
5 Press SEL (select) to finish the setting.
To reactivate clock adjustment, repeat the
same procedure and select “On” in step 4 by
turning the control dial clockwise.
Note:
You must stay tuned to the same station for more than
2 minutes after setting “Auto Adj” to “On.
Otherwise, the clock time will not be adjusted. (This is
because the unit takes up to 2 minutes to capture the
CT data in the RDS signal.)
Other convenient RDS
functions and adjustments
Automatic selection of the station
when using the number buttons
Usually when you press the number button, the
preset station is tuned in.
However, when the preset station is an RDS
station, something different will happen. If the
signals from that preset station are not sufficient
for good reception, this unit, using the AF data,
tunes in to another frequency broadcasting the
same programme as the original preset station is
broadcasting. (Programme search)
The unit takes some time to tune in to another
station using programme search.
To activate programme search, follow the
procedure below.
See also “Changing the general settings
(PSM)” on page 45.
1 Press and hold SEL (select) for more than
2 seconds so that one of the PSM items
appears on the display.
2 Press number button 4 to select “TUNER”—
Tuner category of the PSM settings.
3 Press ¢ or 4 to select
“P(Programme)-Search.
4 Turn the control dial clockwise to select “On.
Now programme search is activated.
5 Press SEL (select) to finish the setting.
To cancel programme search, repeat the same
procedure and select “Off in step 4 by turning
the control dial counterclockwise.
Setting the TA volume level
You can preset the volume level for TA Standby
Reception. When a traffic programme is received,
the volume level automatically changes to the
preset level.
See also “Changing the general settings
(PSM)” on page 45.
1 Press and hold SEL (select) for more than
2 seconds so that one of the PSM items
appears on the display.
EN16-22_KD-LH401[E_EX]f.p65 10/2/04, 9:01 PM21

Table of Contents

Other manuals for JVC KD-Lh401

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JVC KD-Lh401 and is the answer not in the manual?

JVC KD-Lh401 Specifications

Audio Amplifier Specifications IconAudio Amplifier Specifications
maximum power output front50 W per channel
maximum power output rear50 W per channel
continuous power output RMS front19 W per channel into 4 Ω, 40 Hz to 20 000 Hz at no more than 0.8% total harmonic distortion
continuous power output RMS rear19 W per channel into 4 Ω, 40 Hz to 20 000 Hz at no more than 0.8% total harmonic distortion
load impedance4 Ω (4 Ω to 8 Ω allowance)
equalizer control range frequencies60 Hz, 150 Hz, 400 Hz, 1 kHz, 2.4 kHz, 6 kHz, 12 kHz
equalizer control range level±10 dB
frequency response40 Hz to 20 000 Hz
signal-to-noise ratio70 dB
line-out level/impedance5.0 V/20 kΩ load (full scale)
output impedance1 kΩ
CD Player Specifications IconCD Player Specifications
operating voltageDC 14.4 V (11 V to 16 V allowance)
allowable operating temperature0°C to +40°C
dimensions (W × H × D) installation size182 mm × 52 mm × 159 mm
dimensions (W × H × D) panel size188 mm × 58 mm × 12 mm
mass1.6 kg (excluding accessories)
frequency response5 Hz to 20 000 Hz
dynamic range96 dB
signal-to-noise ratio98 dB
max. bit rate mp3320 Kbps
max. bit rate wma192 Kbps
Tuner Specifications IconTuner Specifications
frequency range FM87.5 MHz to 108.0 MHz
frequency range AM (MW)522 kHz to 1 620 kHz
frequency range AM (LW)144 kHz to 279 kHz
usable sensitivity FM11.3 dBf (1.0 µV/75 Ω)
50 dB quieting sensitivity FM16.3 dBf (1.8 µV/75 Ω)
alternate channel selectivity FM (400 kHz)65 dB
frequency response FM40 Hz to 15 000 Hz
stereo separation FM30 dB
capture ratio FM1.5 dB
sensitivity MW20 µV
selectivity MW35 dB
sensitivity LW50 µV

Related product manuals