106 JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
3.2 Power Supply
3.2.29 Current consumption
The supply current measured in each of the 3 supply phases is as follows:
Please notice that the current values shown above is nominal values. Higher values may
appear depending on the quality of the supply.
3.2.30 Emergency stop
Please consult the chapter: Emergency stop considerations, page 384
MAC1500 at nominal shaft load (at 3000RPM)
@400VAC @460VAC @480VAC
2.53 ARMS
2.17 ARMS 2.08 ARMS
MAC1500 at peak shaft load (at 3000RPM)
@400VAC @460VAC @480VAC
7.59 ARMS
6.50 ARMS 6.24 ARMS
MAC3000 at nominal shaft load (at 3000RPM)
@400VAC @460VAC @480VAC
5.06 ARMS
4.34 ARMS 4.16 ARMS
MAC3000 at peak shaft load (at 3000RPM)
@400VAC @460VAC @480VAC
15.18 ARMS
13.00 ARMS 12.48 ARMS
MAC4500 at nominal shaft load (at 3000RPM)
@400VAC @460VAC @480VAC
7.59 ARMS
6.51 ARMS 6.24 ARMS
MAC4500 at peak shaft load (at 3000RPM)
@400VAC @460VAC @480VAC
22.77 ARMS
19.50 ARMS 18.72 ARMS