JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 235
5.6 Expansion Mod. MAC00-FC2/FC4/FC41
5.6.61 MAC00-FC2 with cables (optional)
If a number is added after the basic type number, for example MAC00-FC2-10, this suffix
indicates that the module is fitted with 10 m of cable in the I/O. The I/O cable covers all
the signal lines, i.e. RS232, Digital input 1-4, Limit inputs NL and PL and the Digital out
-
puts 1-4
**: The light green wire (CV) can be difficult to distinguish from the green wire (TX) on
some cables.
Digital Inputs - Internal connector J2
Signal name Pin no. Description Wire colour
IN1 1 Digital input 1 Red/black
IN2 2 Digital input 2 Green/black
IN3 3 Digital input 3 Violet
IN4 4 Digital input 4 Violet/white
NL 5 Negative limit input - If not used, do not connect. Grey
PL 6 Positive limit input - If not used, do not connect. Grey/black
IO- 7
I/O ground. This ground is shared with the output
ground
Pink/black
NC 8 (Reserved) Black/white
CV 9 Secondary supply. Used during emergency stop Light green **
CV 10 Secondary supply. Used during emergency stop White
Digital Outputs - Internal connector J4
Signal name Pin no. Description Wire colour
O+ 1
Supply for outputs - Must be connected to an ext.
supply.
Red/white
O1
2 Digital output 1 - PNP output Green/white
O2 3 Digital output 2 - PNP output Yellow/black
NC 4 (Reserved) Blue/white
NC 5 (Reserved) Orange/white
NC 6 (Reserved) Brown/white
NC 7 (Reserved) Pink
IO- 8
I/O ground. This ground is shared with the input
ground
Black
Interface - including analogue input - Internal connector J1
Signal name Pin no. Description Wire colour
TXPD 1 Transmit pull-down (Connect to TX if addr. not used). Red
TX 2 RS232 Transmit (Connect to TXPD if addr. not used). Green **
RX 3 RS232 Receive Yellow
GND 4 Ground for RS232 Blue
AIN
5 Analogue input +/-10V or Zero sensor input Orange
GND 6 Ground for AIN Brown
Cable Screen
The cable-screen is internally connected to motor housing. Externally it must be connected to earth.
Unused wire
Orange/Black - is not used internally. It must be left unconnected.