JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 247
5.7 Expansion Module MAC00-FD4
5.7.3 Node-id, Baud-rate and Termination setup
The 10-way dip switch (SW1) is used to select the node ID and the Baud-rate. Switches
1-6 select the node ID, and switches 8-9 select the Baud-rate. The 2-way dip switch
(SW2) is used to enable termination. When both switches are on, the termination is en
-
abled.
MAC00-FD4 Dip switch settings
Dip 1-6 - Node-id setting
Dip 7 - Node-id set by software
(address range 0-63)
TT1017GB
Mini dip-switch
SW1
SW2
Dip 8-9 - Baud rate
Dip 1-2 - Line termination
(Baud rate setting 125k to 500k)
OFF ON
connectors
Dip Switches placed
on the rear side of the
module
Rear side of the MAC00-FD4
Dip-switch location on the
MAC00-FD4 Expansion module
Te r m . e n a b l e d
Both set to OFF =
Term. disabled
Dip-switch 10 is not used.
Set in position “ON”.
SW1 default settings =
all set in position “ON”
SW2 default settings =
Both switches in position “OFF”