298 JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
5.10 Expansion module MAC00-P4/P5
5.10.5 General power supply description
The MAC00-P5 module can only be used in the MAC400 motor. The diagram below
shows how to connect power to a MAC400 motor mounted with a MAC00-P5.
Please notice that the voltage connected to CVI1 and P+ (only -MAC00-P4) must stay
in the range +12-32VDC. Precautions must therefore be taken if the system also con
-
tains MAC50, 95, 140 or 141 which may require 48VDC in order to reach maximum mo-
tor speed.
See also the general power supply description Power Supply, page 89.
TT1168GB
MAC50-141 Motor
with MAC00-B1,
B2 or B4
MAC400 Motor
with MAC00-Px
P+
P+
P-
GND
CVI1
Power
Supply
Power
Supply
Control Volt.
Mains 115 or 230VAC
Control voltage
Only MAC50-141 with
B2 or B4 (Optional)
O+
Main supply
line is used for each motor.
Power supply
Make sure that all
involved units are
connected to the same
potential
GND
+18-32VDC
(control voltage)
+8-48VDC
(Bus voltage)
Typical power supply connection to a MAC140 and a MAC400
mounted with a MAC00-B1, B2 or B4 and Px modules.
The terminal P+
do not exist on
MAC00-P5.
Use only CVI1