JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 363
6.2 Torque Curves
Supply voltage = See individual plot
Ambient temperature = 0°C4
«Torque» setting = 300%
Load setting = 1.0
Operation above 3000 RPM
can be done, but losses in
the motor make it impossible
to operate in this area continously
Nm Oz./Inch
1000
>3600RPM =
Overspeed error
4.0
708
3.0
566
2.0 425
1.0
142
0
2000 3000 4000
RPM
MAC400 Torque versus speed
Nm Oz./Inch
1000
>3600RPM =
Overspeed error
8.0
1133
6.0
850
4.0 566
2.0
283
0
2000 3000 4000
RPM
MAC800 Torque versus speed
Nm Oz./Inch
1000
>3600RPM =
4.0
708
3.0
566
2.0 425
1.0
142
0
2000 3000 4000
RPM
MAC402
1000
15.0
2128
10.0
1419
5.0 709
0
2000 3000 4000
RPM
Overspeed error
30.0
4256
20.0
2838
10.0 1419
0
2000 3000 4000
RPM
MAC1200 Torque versus speed
with fan cooling
Torque versus speed
without fan cooling
MAC4500 Torque versus speed
without fan cooling
MAC4500 Torque versus speed
with fan cooling
RPM
RPM
Supply: 400 to 480VAC (3 phases)
Supply: 400 to 480VAC (3 phases)
Supply: 400 to 480VAC (3 phases)
Supply: 400 to 480VAC (3 phases)