JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 383
6.6 Installation instructions
Rule 5 - Precautions concerning MAC800-D3 and -D6.
The MAC800-D3 and MAC800-D6 is offering IP65 protection. To obtain this protection
degree it is very important that the various components are mounted and fasten properly
according to the illustration below.
TT1286-01GB
4 x Torx M2.5 must be
tightened with a torque
of minimum 0.8 to 1.0 Nm
The cable gland must be tightened with minimum 2.0 Nm against
the plate but also the top around the cable must be tightened with
minimum 2.0 Nm
Please notice !
. The cable used must be with a diameter
of 5 to 9 mm in order to be tight