JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 73
2.14 Rotary table option
2.14.2 Configuration via MacTalk.
When using MacTalk for configuration the following parameters are used:
The desired
Rotary table selection
is selected here at the tab.
Advanced
The working range can be defined here
after selecting the type of turn table mode.
Minimum is the lowest position possible
to reach and maximum is the highest position
that can be reached. Both in encoder counts.
Both values are refering to the zero
position found during the optional
Homing
or alternatively the zero point defined if using
an absolute multiturn encoder.
After the setup is done please remember to
save it in the permanent memory by pressing
the button.
Save in Motor