EasyManua.ls Logo

JVL MAC050 - Page 94

JVL MAC050
478 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90 JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
3.2 Power Supply
3.2.3 Dimensioning power supply and fuse (Only MAC050 to 141)
The power supply must be dimensioned according to the actual motor size (MAC050,
95, 140 or 141).
The size of the pre-fuse also depends on the actual model of the MAC motor.
Use the following table to select the power supply and fuse ratings.
See also Power Supplies, page 449 in the appendix which shows the standard power sup-
plies that JVL can offer.
3.2.4 Emergency stop
Please consult the chapter: Emergency stop considerations, page 384
Desired
voltage
MAC050 MAC095 MAC140 or 141
-
Supply
rating
Fuse size Supply
rating
Fuse size Supply
rating
Fuse size
12VDC 20W T4A 40W T6.3A 60W T10A
24VDC 40W T4A 80W T6.3A 160W T10A
48VDC 80W T4A 160W T6.3A 320W T10A
Only MAC050 to 141

Table of Contents