92 JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
3.2 Power Supply
3.2.6 Power supply circuitry (only MAC400)
The MAC400 supply is split into 2 individual circuits with full galvanic isolation between
the circuits. The control circuitry requires a voltage in the range 18 to 32VDC and the
power circuity must be supplied with 90 to 240VAC. Having 2 independent supply cir
-
cuits offers the feature that the supply voltage for the power circuitry (90-240VAC) can
be removed for safety reasons, while the control circuitry can continue operating and
thus keep the position counter updated and keep other vital functions such as communi
-
cation active.
The circuit above is shown with an emergency relay (box) which can be omitted if the
application does not require this safety feature. There are shown examples of Emergency
stop and relay.
See “Emergency stop” on page 384.
The internal power dump is intended to cover 90% of all applications but if the error
message “overvoltage” is monitored, an external power dump resistor must be connect
-
ed between the terminals PD and BO.
3.2.7 Emergency stop
Please consult the chapter: Emergency stop considerations, page 384
See section 5.6.2 for
further information
EMERGENCY
STOP and RELAY
Opto
Isolators
+
-
MAC400 Supply diagram
Mains
Filter
Inrush
limiter
Dump
resistor
Power dump output
Isolation barrier
PD
P+
BO
P-
CM
L2
N
PE
Bus output (320VDC Nom.)
Bus common
P+/- must be per-
manently connected
if control circuitry
must be keept active
while main power is
disconnected.
N
PE
L2
Single phase
0 - 2 0VAC94
+ Earth
Overvolt.
Protection
230VAC
Power
Supply
18-32VDC
+
Optional
All marked in red is connected to this.