4000 Programmable Electronic Pushbutton Lock
4000 Programmable Electronic Pushbutton Lock • PK2971
Page 9
Select the User Code Length and enter the first User code:
1. Press <#> to begin programming.
2. Enter your Master code (8 digits).
3. Press <#>.
4. Enter < 211# >, and then enter the new User code (3 to 6 digits).
5. Press <#>.
6. The green LED should light for 1 second and the lock should beep in the pattern
long, short, short. If you see or hear any other pattern, there is an error.
7. Press <#> to end programming.
8. Write down the User code on the Code Record Log Sheet (User 1, Group 1).
Recommandations: For security reason do not use factory default access code 4000 as
user access code.
The lock ships from the manufacturer with the following default parameters in memory
Refer to sections 2.4 and 2.5 for the procedure to program more user codes and Manager codes,
and for selecting lock features.
Situation Indicator Light
All Manager authorization codes Blank
All User access codes Blank, (except for user code
just
programmed)
Service access code Blank
Passage Mode Off
Lockout Mode Off
Configuration "Commercial setup"
Unlock Time 5 seconds
Buzzer Volume 5
Tamper Shutdown time 4 minutes
Tamper Shutdown counter 6 times
Lock ID 0000
Privileged users none defined 0000
Master Code 12345678
Access Code 4000