EasyManuals Logo

KAESER SM 7.5 User Manual

KAESER SM 7.5
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
Fig. 32 Changing the oil filter
1 Oil filter
2 Direction to unscrew
Changing the oil filter
1.
Compressed air!
Compressed air and devices under pressure can injure or cause death if the contained energy
is released suddenly.
Depressurize all pressurized components and enclosures.
2. Unscrew the oil filter anti-clockwise, catch oil spillage and dispose of in accordance with envi‐
ronmental protection regulations.
3. Lightly oil the new filter's gasket.
4. Turn the oil filter clockwise by hand to tighten.
Dispose of parts and materials contaminated with oil in accordance with environmental
protection regulations.
Starting the machine and carrying out a trial run
1. Close all access doors, replace and secure all removable panels.
2. Open the user's shut-off valve between the machine and the air distribution network.
3. Switch on the power supply and reset the maintenance interval counter.
4. After approx. 10 minutes of operation: Check the cooling oil level and top up if necessary.
5. Switch off the machine and check visually for leaks.
10.18 Changing the oil separator cartridge
The oil separator cartridge cannot be cleaned.
10 Maintenance
10.18 Changing the oil separator cartridge
9_5875 33 USE
Operator Manual Screw Compressor
SM Tri-Voltage, SIGMA CONTROL 2
73

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SM 7.5 and is the answer not in the manual?

KAESER SM 7.5 Specifications

General IconGeneral
BrandKAESER
ModelSM 7.5
CategoryAir Compressor
LanguageEnglish

Related product manuals