5. USING THE MENU
Select “Menu” on the rotary switch and navigate using the function buttons:
U
= Scroll up
V
= Scroll down
= Enter
MAIN
MENU
SUB MENU OPTIONS / COMMENTS
SETUP SET FUEL
NAT GAS, L OIL, PROPANE, BUTANE, LPG,
PELLETS (wood)
N Å C Æ G
EfC = condensing boilers
EfN = nett efficiency, EfG = gross efficiency,
KANE425 always defaults to EfC on start-up
SET TIME
HH:MM:SS format
e.g. 7 am = 07:00:00, 7pm = 19:00:00
SET DATE DD/MM/YY format
EXIT
PRESSURE SMOOTH
OFF = normal response.
ON = slower (damped) response
KANE425 always defaults to normal response
on start-up
RESOLVE
LOW = e.g. 0.01mBar resolution.
HIGH = displays to an extra decimal place.
KANE425 always defaults to low resolution on
start-up
PS UNITS mBar, mmH
2
O, Pa, kPa, PSI, mmHg, hPa, InH
2
O
TIME
LET BY = Set duration of let-by test in minutes.
Default = 1 minute
STABIL’N = Set duration of stabilisation in
minutes. Default = 1 minute
TIGHTN’S = Set duration of tightness test in
minutes. Default = 2 minute
EXIT