AMTOR Directives
While operating your KAM Plus in the AMTOR modes, several directives are available to perform
various functions without returning to the Command mode (cmd:) The directives and their pur-
poses are:
[Ctrl-C][A] Abort link
[Ctrl-C][D] Break link and remain in AMTOR Standby
[Ctrl-C][E] Return to receive mode when transmit buffer is empty in FEC transmit. If
linked, inserts +? (changeover) after all data in the transmit buffer
[Ctrl-C][I] Invert received MARK/SPACE signals and invert transmitted MARK/SPACE if
using AFSK (SSB)
[Ctrl-C][R] Return to receive mode immediately in FEC transmit. (If the transmit buffer
isn't empty, the remaining data will remain in the buffer.) Re-sync if monito-
ring. If linked, inserts +? (changeover) immediately. If the transmit buffer
isn't empty, the remaining data will remain in the buffer.
[Ctrl-C][S] Select the next MARK/SPACE shift (170/425/850/MODEM)
[Ctrl-C][T] Enter transmit mode – seize ISS status
[Ctrl-C][X] Exit AMTOR mode and return to Command mode (packet)
[Ctrl-C][Ctrl-T] Toggle TRACE mode ON/OFF
[Ctrl-W] Send 'Who Are You' inquiry