Summary of G-TOR Directives
[Ctrl-C][A] Abort a link or abort an attempt to link after the first invalid response code
[Ctrl-C][B] Enter data transparency mode (for binary file transfer)
[Ctrl-C][D] Disconnect from the station you are linked to. A changeover will be performed if
required, and the KAM Plus will return to G-TOR Standby mode
[Ctrl-C][E] Changeover from ISS to IRS when all pending data has been transmitted
(ARQ Mode)
Return to receive when transmit buffer is empty (used when calling CQ).
(FEC Mode – AMTOR FEC)
[Ctrl-C][R] Changeover from ISS to IRS immediately.
Return to receive immediately (FEC mode - AMTOR FEC)
[Ctrl-C][T] Seize the link if IRS (ARQ mode)
Enter AMTOR FEC transmit mode
[Ctrl-C][X] Disconnect the link (if linked) and return to PACKET
[Ctrl-C][0] Set automatic baud rate selection
[Ctrl-C][1] Force 100 baud operation (IRS only)
[Ctrl-C][2] Force 200 baud operation (IRS only)
[Ctrl-C][3] Force 300 baud operation (IRS only)
[Ctrl-C][Ctrl-T] Toggle TRACE mode ON/OFF
MODEM BREAK Exit data transparency mode