5
Commands
8bitconv ON | OFF
Default ON
When ON, transmission of 8-bit data is allowed in PACKET and ASCII Modes. When OFF, the 8th
data bit is set to 0 before transmission and all data received in these modes will have the 8th bit
set to 0.
See also: parity
ABaud
n
(
n
= 0, 300, 600, 1200, 1800, 2400, 4800, 9600)
This command sets the baud rate for communication with your computer or terminal. It is set au-
tomatically when you press the * during the KAM Plus autobaud routine.
See also: reset, restore
AMtor [
xxxx
[
xxx
]] characters (or 4, 5 or 9 digits)
Immediate command
This command places the KAM Plus in AMTOR STANDBY Mode. Entering AMTOR xxxx[xxxxx] will
cause the KAM Plus to start a link sequence to the station specified. Entering AMTOR without a
SELCAL will allow your KAM Plus to respond to a link request from another station, or to transmit
Mode B (FEC) AMTOR. To transmit Mode B, type [Ctrl C][T] to begin transmission and type
[Ctrl C][E] to end the transmission. You may also copy Mode B transmission in this mode, if
ARQBBS is OFF.
See also: arqtime, autostrt, canline, fec, lamtor, misschar, mygroup, myselcal, pmode, rephase,
txdtor, txdfec
ARqbbs ON | OFF
Default OFF
When ON, the PBBS in your KAM Plus may be accessed by another station using AMTOR, G-TOR or
PACTOR ARQ. When OFF, the PBBS may only be accessed on PACKET. Note that if ARQBBS is ON,
you will not be able to transmit FEC from the Standby modes.
See also: arqid, pbbs
ARQId
n
(
n
= 0 – 31)
Default 9
This command sets the time interval in 1 minute increments for an automatic CW ID when operat-
ing AMTOR, G-TOR or PACTOR ARQ. The CW ID will be transmitted at the speed set by the
CWSPEED command and he text of the ID is set with the CWIDTEXT command. Setting ARQID to
Ø disables the automatic.
See also: arqbbs
ARQTime
n
(
n
= 1 – 10)
Default 2
This command sets the timeout interval when attempting to link to another station in AMTOR ARQ
Mode. The interval is set in increments of 64 ARQ cycles (approximately 28.8 seconds).
See also: amtor