KPC-9612 Version 5.2 July 19, 1994
25
DIGipeat ON|OFF {ON/ON}
When ON, any packet received that has MYCALL or MYNODE in the digipeat list of its address field
will be retransmitted. Each station included in the digipeat list relays the packet in the order speci-
fied in the address field. Digipeating takes place concurrently with other KPC-9612 operations and
does not interfere with normal connected operation of the station. To disable digipeat operations
(via MYCALL or MYNODE) turn this command OFF.
See also: hid, myalias, mycall, tnygate, mynode
Disconne {immediate command}
This command will initiate an immediate disconnect request on the current I/O stream. When an
acknowledgment is received, your KPC-9612 will display the message ***DISCONNECTED. If you
issue a second disconnect command before receiving the acknowledgment, your KPC-9612 will im-
mediately enter the DISCONNECTED state, but this may leave the other station thinking it is still
connected.
If a user is connected to your PBBS and you want to disconnect that user, give the command DISC
MYPBBS. If a user is connected to you your KA-Node, you can disconnect that user and the station
he is talking to with the command DISC MYNODE
x
where
x
is the node circuit in use.
See also: dbldisc
DISPlay [class] {immediate command}
This command will display a list of parameters in the KPC-9612. If you do not specify a class, all
parameters will be displayed. You may display one specific class of related parameters by specify-
ing the class with the display command. The classes of parameters are:
(A)sync asynchronous port parameters (TNC to computer)
(C)haracter special characters
(I)d ID parameters
(L)ink parameters affecting packet link (to other TNC)
(M)onitor monitor parameters
(P)bbs mailbox parameters
(T)iming timing parameters
Individual parameters may be displayed by entering the command name followed by a carriage re-
turn.
Echo ON|OFF {ON}
When ON, characters received from the terminal are echoed back to the terminal. If you are see-
ing double printing of characters you type, set this command OFF. The KPC-9612 will not echo the
XOFF or XON characters to your terminal. ECHO is automatically disabled when in the Transparent
Mode.
See also: bkondcl, flow