KPC-9612 Version 5.2 July 19, 1994
28
Note: After changing the INTFACE command, you may need to do a soft reset for the new mode
to take effect.
K {immediate command}
This command will place the KPC-9612 in Convers Mode on the current I/O stream. It is synony-
mous with the CONVERS command.
KNtimer
n
(
n
= 0 255) {15}
If there is no activity through a KA-Node circuit for
n
minutes, the KA-Node will disconnect both
the input and output sides of the circuit. Setting KNTIMER to 0 disables this feature.
See also: rnrtime
KNXcon ON|OFF {OFF}
When OFF, the KA-Node will not allow the Xconnect command (cross connecting). When ON, the
Xconnect command is enabled, allowing users to cross-connect from one port of the KPC-9612 to
the other port.
See also: numnodes, mvnode
LCok ON|OFF {ON}
When ON, upper and lower case characters will be sent to the attached terminal. When OFF, lower
case characters are translated to upper case before being sent to the terminal. This case transla-
tion is disabled in Transparent Mode.
LCStream ON|OFF {ON}
When ON, lower case characters may be used in streamswitching. When OFF, stream switching re-
quires upper case characters.
See also: status, streamsw
Leds ON|OFF {ON}
When OFF, the software controlled Front panel LEDs will not light in order to conserve power.
LFadd ON|OFF {OFF}
When OFF, no line feeds will be added to the transmitted data. When ON, the KPC-9612 will ap-
pend a line feed to every carriage return transmitted over the radio.
See also: autolf, cradd