EasyManua.ls Logo

Kärcher K 6 - Technical Data

Kärcher K 6
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English 17
EN IEC 63000: 2018
Conformity evaluation procedure used
2000/14/EC: Annex V
Sound power level dB(A)
K 5, K6
Measured: 88
Guaranteed: 91
K 5 Classic
Measured: 89
Guaranteed: 92
The signatories act on behalf of and with the authority of
the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2023/10/01
We hereby declare that the product described below
complies with the relevant provisions of the following
UK Regulations, both in its basic design and construc-
tion as well as in the version put into circulation by us.
This declaration shall cease to be valid if the product is
modified without our prior approval.
Product: High-pressure cleaner
Type: K 5, K 5 Classic, K6
Currently applicable UK Regulations
S.I. 2001/1701 (as amended)
S.I. 2008/1597 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2016/1091 (as amended)
Designated standards used
EN 60335-1
EN 60335-2-79
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997 + A1: 2001 + A2: 2008
EN 61000-3-2: 2014
EN 61000-3-11: 2000
EN IEC 63000: 2018
Applied conformity assessment procedure
S.I. 2001/1701 (as amended): Schedule 8
Sound power level dB(A)
K 5, K6
Measured: 88
Guaranteed: 91
K 5 Classic
Measured: 89
Guaranteed: 92
The signatories act on behalf of and with the authority of
the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2023/10/01
Technical data
Subject to technical modifications.
Declaration of Conformity (UK)
Electrical connection
Voltage V 220-240
Phase ~ 1
Frequency Hz 50-60
Maximum permissible mains grid
impedance
Ω 0,34 +
j0,21
Power rating kW 2,2
Degree of protection IPX5
Protection class II
Power protection (slow-blowing) A 10
Water connection
Feed pressure (max.) MPa 1,2
Input temperature (max.) °C 40
Input amount (min.) l/min 10
Suction height (max.) m 0,5
Device performance data
Operating pressure MPa 12,0
Max. permissible pressure MPa 16
Water flow rate l/min 6,7
Maximum flow rate l/min 8,5
Detergent flow rate l/min 0,3
High-pressure gun recoil force N 17
Dimensions and weights
Typical operating weight kg 7,5
Length mm 302
Width mm 346
Height mm 849
Determined values in acc. with EN 60335-2-79
Hand-arm vibration value m/s
2
2,1
Uncertainty K m/s
2
0,7
Sound pressure level L
pA
dB(A) 75
Uncertainty K
pA
dB(A) 3
Sound power level L
WA
+ uncer-
tainty K
WA
dB(A) 91

Table of Contents