EasyManua.ls Logo

KB Electronics KBRG-212D - Speed Potentiometer and Voltage Following; Main Speed Potentiometer Connections; Voltage Following Connection

KB Electronics KBRG-212D
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
FIG. 12 – VOLTAGE
FOLLOWING CONNECTION
E. Main Speed Potentiometer The main speed potentiometer can be connected in several
ways using terminals “COM,” “+15,” “SIG” and “-15.” A 5K ohm potentiometer is supplied
with control. (A 10K potentiometer can also be used.) (Warning! Terminals “COM,”
“+15,” “SIG” and “-15" are not isolated from AC line.) Note: Jumper J5 must be in
the “15V” position.
i. Unidirectional operation only – Connect potentiometer to terminals “COM,” “+15,”
“SIG" for forward direction. To operate in reverse direction, connect to “COM,” “SIG,”
and “-15.” See fig. 10.
ii. Bidirectional operation only – Connect to terminals “COM,” “+15,” “SIG,” and “-15"
when using reversing contacts. To operate with a potentiometer, connect to “+15,"
“SIG,” and “-15." See fig. 11.
FIG. 10 – MAIN SPEED POTENTIOMETER CONNECTIONS (Unidirectional)
Forward Reverse
FIG. 11 – MAIN SPEED POTENTIOMETER CONNECTIONS (Bidirectional)
Bidirectional with Reversing Contact Bidirectional with Speed Pot
TB1
POTENTIOMETER
MAIN SPEED
+15VSIG-15V COMTACH EN
*
MAIN SPEED
POTENTIOMETER
TB1
TACH
-15V SIG +15V
COM EN
*
*Note: Arrow indicates increase in motor forward speed.
F. Voltage Following – An isolated analog voltage can
be used in lieu of main speed potentiometer. Connect
signal to terminals “SIG" and “COM.” Note: Terminal
“COM" is common. A positive signal with respect to
terminal “RB1” will produce a positive output to motor.
A negative signal with respect to terminal “COM" will
produce a negative output. A 0 to ±10VDC is required
to operate control from 0 ± full output. (A bipolar
signal isolator, SI-4X [KB P/N 8801], is available as an
option from your distributor.) Note: Jumper J5 must be in the “10V” position. Note: An
isolated signal voltage must be used or catastrophic failure can result.