Operating Instructions | KBL tower space 2000
47
11. Technical Data
Ambient conditions
Installation site
• In dry rooms (booths) with sufficient airing
(intake and discharge)
• Relative humidity: ≤ 70%
• Room temperature: ≤ 30°C (≤ 86°F)
• Minimum height of the room: 2270 mm
(~89.37 inch)
• Only on a non-combustible basement
• Maximum operating altitude: 6500 ft
Weights and measures
Dimensions in inches
(height x width x depth)
85.83 x 55.12 x 55.31 (closed)
85.83 x 55.12 x 77.28 (opened)
Weight approx. 390 kg (~ 859.803 lbs)
Floor plate
max. load capacity
330 lbs
Electrical connection values
Protective class IP 20
Mains voltage 3-phase operation: 3x 220 V / ~ / 60 Hz - 2-phase operation: 2x 220 V / ~ / 60 Hz
Wire cross section
3-phase operation: 4x AWG8 - 2-phase operation: 3x AWG8
THHN cable in a isolation tubing (e.g. flexible metallic conduit, utilizing appropriate connectors)
Fuses
3-phase operation: 3x 40 A (for Canada with ground fault circuit interrupter (FI))
2-phase operation: 2x 63 A (for Canada with ground fault circuit interrupter (FI))
MP3 player
• Supports SD cards up to 1-2 GB (SD) / 4-16 GB (SDHC)
• Supported file system (SD card): FAT16, FAT32
• Supported MP3 files: constant and variable bit rate, 96-320 Kbit/s
Nominal power 10150 W
Central exhaust air discharge
Fan
Minimum exhaust air flow rate: 528344 gal/h
Exhaust-air socket - Diameter 300 mm (~11.811 inch).
Exhaust-air hose Diameter 300 mm (~11.81 inch).
Unit data: KBL Tower space 2000
Tubes 50x megaLine 1972 R 180W