V4.00
25833_EDEBDA0290-0622-1_EN
24
*** Security
SNMP is enabled
SNMP Community Name: public Tel-
net Setup is enabled TFTP Down-
load is enabled Port 77FEh
is enabled
Web Server is enabled
Web Setup is enabled
ECHO is disabled
Enhanced Password is disabled
Port 77F0h is enabled
*** Channel 1
Baudrate 38400, I/F Mode 7F, Flow
00 Port 08000
Connect Mode : C0
Send ‚+++‘ in Modem Mode enabled
Show IP addr after ‚RING‘ enabled
Auto increment source port disa-
bled
Remote IP Adr: --- none ---, Port
00000 DisconnMode : 00
FlushMode : 00
etc.
Change Setup:
0 Server
1 Channel 1
3 E-mail
5 Expert
6 Security
7 Defaults
8 Exit without save
9 Save and exit
Your choice ? 1
Baudrate (38400) ? I/F Mode (7F)
?
Flow (00) ?
Port No (8000) ?
ConnectMode (C0) ? C3
Start Char: (02) ? 02
Send ‚+++‘ in Modem Mode
(Y) ?
Show IP addr after ‚RING‘ (Y) ?
Auto increment source port (N) ?
Remote IP Address : (000)
10.(000) 66.(000) 22.(000) 98
Client-IP-Adresse
Remote Port (0) ? 8000 Client-Port
DisConnMode (00) ?
FlushMode (00) ? 80
Pack Cntrl (00) ? 20
DisConnTime (00:00) ?00:20
SendChar 1 (00) ?
SendChar 2 (00) ?
Change Setup:
0 Server
1 Channel 1
3 E-mail
5 Expert
6 Security
7 Defaults
8 Exit without save
9 Save and exit
Your choice ? 9
Enter 9 to save and apply the changes.
LAN eBus conguration