KEB COMBIVERT 27F5 Series Specifications

General IconGeneral
Series27F5
CategoryInverter
Output Frequency0-400 Hz
Enclosure RatingIP20
Input Voltage380-480 V AC
Power Range0.75-630 kW
Control MethodV/f control, vector control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesCANopen, Profibus, Ethernet
Ambient Temperature-10 to +40 °C
Relative Humidity5 to 95 % (non-condensing)
AltitudeUp to 1000 m above sea level (derating above 1000 m)
Storage Temperature-25…+70 °C

Summary

Preface and General Information

Safety Words and Symbols

Explains signal words and safety signs used in the manual.

Basic Safety Instructions

Target Audience and Qualifications

Defines the intended audience and required qualifications for the manual.

Installation Safety Precautions

Safety precautions and guidelines for installing the drive converter.

Electrical Connection Safety

Safety instructions for connecting the drive converter electrically.

EMC-Compatible Installation and Voltage Testing

Guidelines for EMC installation and voltage testing precautions.

Start-Up and Operation Safety

Instructions and warnings for initial start-up and operation.

Maintenance and Repair Safety

Procedures and warnings for maintenance and repair.

Product Description

Specified Application and Restrictions

Defines intended use, restrictions, and residual risks.

Technical Data: Operating Conditions

Electromagnetic Compatibility (EMC) Details

Specifies EMC emitted interference and immunity levels.

Unit Data Overview

Installation Guidelines

EMC-Compatible Control Cabinet Installation

Guidelines for installing the drive converter within a control cabinet for EMC.

Connecting the COMBIVERT F5-AIC

Input Terminal Descriptions

Explains the function of various input terminals on the drive converter.

Terminal Cross-Sections and Tightening Torques

Specifies wire cross-sections and tightening torques for terminals.

Functional Description of Start-Up Procedure

Describes the functional sequence of the start-up procedure.

Connection of the Control Board

Terminal Block X2 A Assignment

Pin assignments and functions for terminal block X2A.

Operating the Drive Converter

Operation with Digital Operator

Instructions for operating the drive converter with a digital operator.

Keyboard Operation and Parameter Adjustment

How to use the keyboard for parameter and value adjustment.

Dimensioning Instructions and Data

Technical Data of COMBIVERT Drive Converters

Detailed technical data for COMBIVERT drive converters.

Technical Data for COMBIVERT F5 AIC Devices

Specific technical data for COMBIVERT F5 AIC devices.

Cooling System Installation and Requirements

Installation of Liquid-Cooled Devices

Guidelines for installing liquid-cooled drive converters.

Coolant Temperature Management

Guidelines for managing coolant temperature.

Moisture Condensation Prevention

Warnings and prevention of moisture condensation.

Series Connection Schemes for Cooling Circuits

Diagrams for series connection of cooling circuits.

Parallel Connection Schemes for Cooling Circuits

Diagrams for parallel connection of cooling circuits.