GB - 9
Technical Data
2. Technical Data
2.1 Operating conditions
Standard Standard/
class
Instructions
Denition acc.
EN 61800-2 Inverter-product standard: Ratedspecications
EN 61800-5-1 Inverter-product standard: General safety
EN 61800-5-2 Inverter-product standard: Functional safety
Site altitude
max. 2000 m above sea level
With site altitudes over 1000 m a derating of 1 % per
100 m must be taken into consideration.
Ambient conditions during operation
Climate
Temperature
EN 60721-3-3
3K3
extended to -10…45 °C
With temperature over 45°C to max. 55°C a derating of
5 % per 1 K must be taken into consideration.
Humidity 3K3 5…85 % (without condensation)
Mechanical Vibration
Track EN50155 max. amplitude of a vibration 1 mm (5…13 Hz)
max. acceleration amplitude 7 m/s² (13…100 Hz)
1 m/s² (100…200 Hz)
Germ. Lloyd Part 7-3
Contamination
Gas
EN 60721-3-3
3C2
Solids 3S2
Ambient conditions during transport
Climate
Temperature
EN 60721-3-2
2K3
Humidity 2K3 (without condensation)
Mechanical
Vibration 2M1 15 m/s² (200…500 Hz)
Surge 2M1 50 g/30 ms; drop from 0.25 m height
Contamination
Gas 2C2
Solids 2S2
Ambient conditions for the storage
Climate
Temperature
EN 60721-3-1
1K4
Humidity 1K3 (without condensation)
Contamination
Gas 1C2
Solids 1S2
Type of protection EN 60529 IP20
Environment IEC 664-1 Pollution degree 2
Denition acc. EN 61800-3 Inverter-product standard: EMC
EMC emitted interference
Cable-based interferences C1/C2 see chapter 3.2.2.3
Radiated interferences C2
Interference immunity
Static discharges EN 61000-4-2
8 kV
4 kV
AD (air discharge)
CD (contact discharge)
Burst - Ports for process measu-
rement control lines and signal
interfaces
EN 61000-4-4 1 kV tested with 2 kV
Burst - Power ports EN 61000-4-4 2 kV tested with 4 kV
Surge - Power ports
EN 61000-4-5
1 kV
2 kV
Phase-phase
Phase-ground
Immunity to conducted disturban-
ces, induced by radio-frequency
elds
EN 61000-4-6 10 V 0.15-80 MHz
Electromagnetic elds EN 61000-4-3 10 V/m
Voltage variation /
voltage drop
EN 61000-2-1
+10 %, -15 %
90 %
Voltage unsymmetries /
Frequency changes
EN 61000-2-4
3 %
2 %