KC-P30 Maintenance
Installation manual V3.28
49
© KEBA
10 Maintenance
10.1 Replacing the fuse
Fuse Current / Voltage Type Dimensions
F1 6.3 A / 250 V
Delay with high breaking
capacity (>1500A) (T) (H)
5 x 20 mm fuse
To replace the fuse, proceed as follows:
1) Switch off the supply voltage of the charging station.
2) Remove the housing cover, the connection panel cover, and the terminal
cover.
If there is a seal on the connection panel cover or terminal cover, it may
only be removed by an authorized person! After changing the fuse, the
seal must be replaced.
3) Using a screwdriver, press into the opening of the fuse holder.
4) Screw the fuse holder counterclockwise until it springs forward automati-
cally by the spring.
5) Replace the fuse.
6) Press the fuse holder in and tighten clockwise.
7) Mount the housing covers on the charging station again.
The fuse has now been replaced.
10.2 Troubleshooting
Further information (e.g. operating and configuration instructions) and con-
tact details are available on our website: