KC-P30 Technical data
Installation manual V3.28
53
© KEBA
12 Technical data
12.1 General
Charge mode:
Mode 3 in accordance with IEC 61851-1
AC charging
Overvoltage category: III in accordance with EN 60664
Protection class: I
Protection class: IP54
Protection against mechanical impact: IK08 (except for cylinder lock)
Rated short-time withstand current:
< 10 kA (effective value in accordance with
EN61439-1)
Residual direct current detecting device
(RDC-DD):
> 6 mA (characteristic in accordance with
IEC62955, <10s)
Ventilation during charging: Not supported
12.2 Power supply
Power consumption e-series
Rated supply voltage (Europe): 230 V
Internal consumption: Idling: 2 W, plugged in: 3 W, charging: 5.5W
Rated current (configurable):
10 A / 13 A / 16 A / 20 A / 25 A / 32 A
1-phase
Line frequency: 50 Hz
Mains forms: TT / TN / IT
Power supply b-series / c-series
Rated supply voltage (Europe): 3 x 230 V / 400 V
Internal consumption:
Idling: 3 W, plugged in: 4.5 W, charging:
6.5W
Rated current (configurable):
10 A / 13 A / 16 A / 20 A / 25 A / 32 A
1-phase or 3-phase
Line frequency: 50 Hz
Mains forms: TT / TN / IT
Power supply x-series
Rated supply voltage (Europe): 3 x 230 V / 400 V
Internal consumption: Idling: 4 W, plugged in: 5 W, charging: 7W
Rated current (configurable):
10 A / 13 A / 16 A / 20 A / 25 A / 32 A
1-phase or 3-phase
Line frequency: 50 Hz
Mains forms: TT / TN / IT