KC-P30 Technical data
Installation manual V3.28
54
© KEBA
Power loss
Socket: 20 W at 22 kW
Cable (4 m): 70 W at 22 kW
Cable (6 m): 100 W at 22 kW
Supply terminals
Type: Spring-type terminal
Cable feed: Top (surface), back side (flush)
Connection cross-section of the supply:
Minimum cross-section (depending on the
cable and the type of installation)
● 16 A rated current: 5 x 2.5 mm
2
● 32 A nominal current: 5 x 6.0 mm
2
Cross section:
● Rigid / flexible: 0.2 – 16 mm
2
● Flexible with wire end sleeve with / with-
out plastic sleeve:
0.25 – 10 mm
2
AWG: 24 – 6
Stripping length: 12 mm
Temperature rating: 105 °C
12.3 Cable / Socket
Cable versions:
(For rating, see rating plate on the cable)
● Type1 cable: up to 32A/ 230VAC in
accordance with EN62196-1 and SAE-
J1772
● Type2 cable: up to 32A/ 400VAC in
accordance with EN62196-1 and VDE-
AR-E 2623-2-2
Socket variants:
● Type2 standard socket: 32A/
400VAC in accordance with
EN62196-1 and VDE-AR-E 2623-2-2
● Type2 standard socket: 32A/
400VAC in accordance with
EN62196-1 and VDE-AR-E 2623-2-2
with Shutter
12.4 Ambient conditions
Use: Inside and outside area
Access limitations at set-up location: Limited and unlimited access
Installation (stationary): On the wall or on a floor-mounted column.
Operating temperature:
● 16 A: -25 °C to +50 °C (without direct sunlight)
● 32 A: -25 °C to +40 °C (without direct sunlight)
Storage temperature: -25 °C to +80 °C