KC-P30 Technical data
Installation manual V3.28
57
© KEBA
MID
Accuracy class: Class B (according to EN 50470-1 / -3)
National approval
Conformity to measurement and calibration
standards:
National authorization for auxiliary equipment
Accuracy class:
Class A (according to EN 50470-1 / -3) at the
dispensing point
Generation of a measurement data record for
each charging session:
● Format: OCMF
● Energy of the charging session
● Customer identification
● Signature
Long-term memory for measurement data in
the device:
> 20.000 charging sessions
Instant display of the measurement data:
● Device-specific display with lighting and
dimmer function
● Display of the energy of a charging ses-
sion
● Display of the transaction ID
Remote transmission of the measurement
data:
● In the network using a device-specific
web interface
● Via OCPP backend
Measured data verification: https://transparenz.software/
12.8 Dimensions and weight
Version with standard socket (Type 2)
Height / Width / Depth: 516 mm / 240 mm / 166 mm
Weight:
Approx. 4.8 - 5 kg (depending on device ver-
sion)