14/10/20
KLP
Low Prole
Evaporator
Air, Electric, & Hot Gas Defrost
Electrical Power:
115/1/60, 208-230/1/60, 208-230/3/60
Bulletin K30-KLPD-PDI-4
Part # 1109283
PRODUCT DATA &
INSTALLATION
PRODUCT SUPPORT
web: www.k-rp.com/klp
email: evaps@k-rp.com
call: 1-844-893-3222 x520
scan:
2
2
3 - 5
6 - 11
11 - 14
15 - 20
21
22
23
24
25
26 - 29
30 - 31
32 - 33
34
35
BACK
INCLUDES RATINGS FOR
STANDARD ON ALL MODELS
see page 15 for details
New Generation "D"
CONTENTS Page
Nomenclature.............................................................................................................................
Features & Options.....................................................................................................................
Selection Data............................................................................................................................
Electrical Data............................................................................................................................
Wiring Diagrams - Models with standard
motors ..................................................
Wiring Diagrams - Models with .....................................................................................
Annual Walk-In Energy Factor (AWEF) Ratings..............................................................................
Dimensional Data.......................................................................................................................
Shipping Weights........................................................................................................................
Recommended Expansion Valve Selections..................................................................................
Expansion Valve Selections - Models with
......................................................................
Defrost Kit and Fuse Package Selections / Details .......................................................................
Installation Instructions..............................................................................................................
Hot Gas Piping Schematics.........................................................................................................
Project Information.....................................................................................................................
Product Support Resources: Service Parts, Troubleshooting, Warranty, etc....................................
As Built” Service Parts List.........................................................................................................
Question and Answer IconNeed help?

Do you have a question about the KeepRite KLP Series and is the answer not in the manual?

Summary

SELECTION DATA

Medium Temperature 6 FPI Selection Data

Capacity and charge data for medium temperature, 6 FPI models across various refrigerants.

Low Temperature 6 FPI Selection Data

Capacity and charge data for low temperature, 6 FPI models across various refrigerants.

Low Temperature 4 FPI Selection Data

Capacity and charge data for low temperature, 4 FPI models across various refrigerants.

ELECTRICAL DATA

Electrical Data: 115;1;60 Air;Hot Gas Defrost

Fan motor electrical specifications for 115V, air/hot gas defrost models.

Electrical Data: 208-230;1;60 Air;Hot Gas Defrost

Fan motor electrical specifications for 208-230V, air/hot gas defrost models.

Electrical Data: Electric Defrost Models

Fan motor & defrost heater specs for 208-230V electric defrost models.

Electrical Data: 115;1;60 Hot Gas Defrost

Fan motor & drain pan heater specs for 115V hot gas defrost models.

Electrical Data: 208-230;1;60 Hot Gas Defrost

Fan motor & drain pan heater specs for 208-230V hot gas defrost models.

WIRING DIAGRAMS

Wiring Diagrams: Air Defrost

Diagrams for 115/1/60 and 208-230/1/60 air defrost models.

Wiring Diagrams: Electric Defrost

Diagram for 208-230/1/60 electric defrost using contactor.

Wiring Diagrams: Multi-Evaporator Electric Defrost

Diagram for multi-evaporator electric defrost systems.

Wiring Diagrams: Hot Gas Defrost

Diagrams for hot gas defrost with alternate fan speed methods.

AVAILABLE OPTIONS

ESP+ Control Technology

Benefits and features of the ESP+ evaporator control system.

EXPANSION VALVE SELECTIONS

Recommended TXV Selections

TXV and solenoid valve recommendations for various models and refrigerants.

Factory Installed TXV for ESP+

Factory valve options for ESP+ models, split by temperature and FPI.

DEFROST KIT & FUSE PACKAGE SELECTIONS

Defrost & Fuse Packages: Medium;Low Temp 6 FPI

Kits and packages for medium and low temp 6 FPI models.

Defrost & Fuse Packages: Low Temp 4 FPI

Kits and packages for low temperature 4 FPI models.

Defrost Kit Details

Detailed descriptions of available defrost kit part numbers and their components.

Fuse Package Details

Detailed descriptions of available fuse package part numbers.

INSTALLATION INSTRUCTIONS

General Installation

Guidelines for inspection, application, location, and mounting of the evaporator.

TXV and Nozzle Installation

Procedures for TXV and nozzle selection and installation for optimal performance.

Drain Line & System Check

Instructions for drain line installation, heating, and pre-startup checks.

Maintenance & Post-Start

Routine maintenance, system checks, and initial startup procedures.

HOT GAS PIPING SCHEMATICS

Hot Gas Piping: Standard Configurations

Schematics for standard reverse cycle and 3-pipe defrost piping.

Hot Gas Piping: Optional Configurations

Schematics for optional defrost configurations, drain pan loops, and solenoid valves.