A-63
APPENDIX A
Scripts
node[1].smub.reset() --Reset SMU
node[2].smua.reset() --Reset SMU
errorqueue.clear() --Clear the error queue
--Configure drain-source SMU (TSP-Link Node[1] SMUA) source and measure settings
node[1].smua.source.func = node[1].smua.OUTPUT_DCVOLTS
node[1].smua.source.autorangev = node[1].smua.AUTORANGE_ON --Enable source
autorange
node[1].smua.source.levelv = l_vds_source
node[1].smua.source.limiti = l_icmpl
node[1].smua.measure.autorangev = node[1].smua.AUTORANGE_ON --Enable measure
autorange
node[1].smua.measure.nplc = l_nplc --Measurement integration rate
--Configure gate-source SMU (TSP-Link Node[1] SMUB) source and measure settings
node[1].smub.source.func = node[1].smub.OUTPUT_DCVOLTS
node[1].smub.source.autorangev = node[1].smub.AUTORANGE_ON --Enable source
autorange
node[1].smub.source.levelv = l_vds_source
node[1].smub.source.limiti = l_icmpl
node[1].smub.measure.autorangev = smub.AUTORANGE_ON --Enable measure autorange
node[1].smub.measure.nplc = l_nplc --Measurement integration rate
--Configure substrate-source SMU (TSP-Link Node[2] SMUA) source and measure settings
node[2].smua.source.func = node[2].smua.OUTPUT_DCVOLTS
node[2].smua.source.autorangev = node[2].smua.AUTORANGE_ON --Enable source
autorange
node[2].smua.source.levelv = l_vsb_source
node[2].smua.source.limiti = l_icmpl
node[2].smua.measure.autorangev = node[2].smua.AUTORANGE_ON --Enable measure
autorange
node[2].smua.measure.nplc = l_nplc --Measurement integration rate
node[1].smua.source.output = smua.OUTPUT_ON --Enable Output
node[1].smub.source.output = smub.OUTPUT_ON --Enable Output
node[2].smua.source.output = smua.OUTPUT_ON --Enable Output
--Execute sweep
for l_i = 1, l_vgs_steps do
--smua.source.leveli = l_source_val
delay(0.010) --Delay
l_id_curr[l_i] = node[1].smua.measure.i() --Measure drain-source current
l_vgs_volt[l_i] = node[1].smub.measure.v() --Measure gate-source voltage
l_isb_curr[l_i] = node[2].smua.measure.i() --Measure substrate-source
current

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley Series 2600 and is the answer not in the manual?

Keithley Series 2600 Specifications

General IconGeneral
ModelSeries 2600
Measurement FunctionsVoltage, Current, Resistance, Power
ResolutionUp to 6.5 digits
Current Source RangeUp to 10A
Communication InterfacesGPIB, USB
ApplicationsSemiconductor testing
CategorySource Measure Unit (SMU)
ChannelsSingle or Dual Channel (varies by model)