To set register bits:
status.operation.instrument.smuX.* = status.operation.CALIBRATING
status.operation.instrument.smuX.* = status.operation.CAL
status.operation.instrument.smuX.* = status.operation.MEASURING
status.operation.instrument.smuX.* = status.operation.MEAS
status.operation.instrument.smuX.* = status.operation.PROMPTS
status.operation.instrument.smuX.* = status.operation.PRMPTS
status.operation.instrument.smuX.* = status.operation.USER
status.operation.instrument.smuX.* = status.operation.PROGRAM_RUNNING
status.operation.instrument.smuX.* = status.operation.PROG
To read registers:
print(status.operation.instrument.smuX.*)
print(status.operation.instrument.smuX.condition)
print(status.operation.instrument.smuX.event)
B0
B0
B4
B4
B11
B11
B12
B14
B14
To set register bits:
status.operation.instrument.* = status.operation.instrument.SMUA
status.operation.instrument.* = status.operation.instrument.SMUB
To read registers:
print(status.operation.instrument.*)
print(status.operation.instrument.condition)
print(status.operation.instrument.event)
B1
B2
To set register bits:
status.operation.calibrating.* = status.operation.calibrating.SMUA
status.operation.calibrating.* = status.operation.calibrating.SMUB
To read registers:
print(status.operation.calibrating.*)
print(status.operation.calibrating.condition)
print(status.operation.calibrating.event)
B1
B2
To set register bits:
status.operation.measuring.* = status.operation.measuring.SMUA
status.operation.measuring.* = status.operation.measuring.SMUB
To read registers:
print(status.operation.measuring.*)
print(status.operation.measuring.condition)
print(status.operation.measuring.event)
B1
B2
Table D-7 (cont.)
Operation event commands
Command
1
Bit
1. * = '.ntr', '.ptr' and '.enable'; smuX = smua or smub.
** = '.ntr', '.ptr', '.enable', and ‘.condition’; smuX = smua or smub.

Table of Contents

Other manuals for Keithley SourceMeter 2602

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley SourceMeter 2602 and is the answer not in the manual?

Keithley SourceMeter 2602 Specifications

General IconGeneral
BrandKeithley
ModelSourceMeter 2602
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals