Prevention of welding, if the gas pressure is not sufficent by the wire feeder unit.
Stopping of welding, if shielding gas pressure disappears during welding.
When gas guard has prevented welding, error message E.12 appears on welding panel displays.
Shielding gas flow meter / regulator. Regulation range 5-25l/min. The display is calibrated for shielding gas
ArCO2 (75%Ar, 25%CO2)
Hanging onto boom
The lift hook is mounted to handle of the FEED. The wire feeder unit´s position
depends on the lift hook hole position.
OPERATION DISTURBANCES
The amount of use and the working environment should be taken into consideration when planning the frequen-
cy of maintenance of the FEED400. Careful use and preventive maintenance will help to ensure trouble-free
operation.
The following maintenance operations should be carried out at least every six months:
Check:
The wear of the grooves of the feed rolls. Excessive wear of grooves causes
problems in wire feed.
The wear of the wire guide tubes of the wire feeder unit. Badly worn feed rolls and
wire guide tubes should be discarded.
The wire guide tube in the gun should be set as near the feed rolls as possible, but
not touching them and the wire must follow a straight line from the end of the tube
to the groove of the feed roll.
Reel brake adjustment.
Electric connections
* oxidized couplings must be cleaned
* loose couplings must be tightened
Clean dust and dirt from the equipment.
When using compressed air, always protect your eyes with proper eye protec-
tion.
In case of problems contact your KEMPPI dealer.
twice a
year
REGULAR MAINTENANCE OF EQUIPMENT
Kemppi service repair shops make regular maintenance according to agreement.
The major points in the maintenance procedure are as follows:
Cleaning of the equipment
Checking and maintenance of the welding tools
Checking of connectors, switches and potentiometers
Checking of electric connections
Metering units checking
Checking of mains cable and plug
Damaged parts or parts in bad connection are replaced by new ones
Maintenance testing. Operation and performance values of the equipment are checked, and adjusted when
necessary by means of test equipment.