12 – Kempact™ pulse 2800 mVu automotiVe / 0709 © Kemppi oy
Parameter Name Nr Display 1-MIG Pulsed
MIG
Factory
value
Unit Explanation
PostGasTime 1 PoG X X Curve s PostGas time 0.0…9.9 s
PreGasTime 2 PrG X X Curve s PreGas time, functions by
2T 0.0…9.9 s
HotStartLevel 11 Hot X X 30 % Hot start ratio to welding
power 50…+75%
HotStartTime 2T 12 H2t X X 2 s 2T Hot start timer 0.1-9.9 s
CraterFillLevel 14 CFL X X 30 % Welding end level 10-90 %
CraterFillSlope 15 CFS X X 1 s/10m Wire slowing-down
1…20 s/10m
CreepStartLevel 17 CSL X X Syn Wire speed start value
10…90
CreepStartSlope 18 CSS X X 0 s/10m Wire speed up time
0.1…5 s/10m
DoubleFrequency 21 dFr
StartPower 31 StP X X 0 Start power control
-9…0…+9
PulseCurrent 33 PuC X 0 % Pulse top current control
10…+15%
ArcLength
AdjRange
41 ALr X X 0 % Arc length adjustment
range 50…+75%
Calibration 42 CAL X X 1 V/100A Setting mid value of arc
length ne adjustment
0.0…10.0 V/100A
WFS
51 FS 18 m/min Wire feed maximum
18 or 25 m/min
Gun 53 Gun On liquidcooled thermal
protection on/off
GunRemote 54 GrE On Disabling of gun remote
control automatic
identication
Display reset
time
81 dLY X X 5 s 1...20 s
PRG INFO - feeld
selection
82 diS X X 1 1,2,3
Restore 99 FAC X OFF Restoring factory settings
(OFF=no reset,
Pan=panel and setup
ALL= also memory
channels)
Setup functions on pulse panel