2.7.2 Loading and threading the ller wire
1., 10.
1. Open the ller wire cabinet door by pressing the orange door latch button and installing
the ller wire spool in such a way that it rotates counter clockwise. You can use either a
5 kg (diameter 200 mm) or 1 kg (100 mm) ller wire spool with MinarcMig Evo by adding
or removing the 200 mm spool adapter.
2.
5 KG
1 KG
2.
2. Attach the wire spool friction plate, lock and secure the spool.
3. Release the ller wire end from the spool, but carefully holding on to it all the times.
4. Straighten the wire end for approximately 20 cm and cut the wire in the middle of the
straightened section.
5. Smooth the sharp ller wire end
5.
9