EasyManua.ls Logo

KERN FCB Series User Manual

KERN FCB Series
334 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
e-Mail: info@kern-sohn.com
Тел.: +49-[0]7433- 9933-0
Факс: +49-[0]7433-9933-149
Интернет: www.kern-
sohn.com
Инструкция по эксплуатации
Компактные весы
KERN FCB
Версия 1.1
01/2009
RUS
FCB-BA-rus-0911

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the KERN FCB Series and is the answer not in the manual?

KERN FCB Series Specifications

General IconGeneral
BrandKERN
ModelFCB Series
CategoryScales
LanguageEnglish

Summary

Technical Data

Declaration of Conformity

Basic Information (General)

Proper Use

Intended use as a non-automatic balance for manual weighing.

Improper Use

Avoid dynamic weighing, permanent load, overloading, explosive environments, and modifications.

Warranty Conditions

Warranty void if manual ignored, use is outside scope, or damage occurs.

Basic Safety Precautions

Follow Operation Manual Instructions

Carefully read the operation manual before setup and commissioning.

Personnel Training

Appliance must be operated and maintained only by trained personnel.

Transport and Storage

Testing Upon Acceptance

Check packaging and appliance immediately upon receipt for possible visible damage.

Packaging for Return

Keep original packaging for returns and secure all parts to prevent damage during transit.

Unpacking, Setup, and Commissioning

Installation Site Requirements

Place balance on a firm, level surface away from heat, sunlight, draughts, and vibrations.

Unpacking Procedure

Carefully remove balance from packaging, remove protective cover, and place at workstation.

Balance Installation

Ensure the balance is installed so the weighing plate is exactly horizontal.

Scope of Delivery

Lists included accessories: balance, weighing plate, transport security, power supply, cover, manual.

Basic Structure Setup

Place on solid base, remove security, pull foil, attach plate.

Mains Connection

Use only original KERN mains adapters with matching voltage for power supply.

Battery Operation

Connect 9V battery; auto-switch-off can be activated/deactivated in menu.

Peripheral Device Connection

Disconnect power before connecting peripherals; use KERN accessories.

Initial Commissioning

Ensure balance reaches operating temperature and is connected to power before first use.

Importance of Adjustment

Adjust balance to local gravity/temp for accuracy; periodic adjustment recommended.

Adjustment Procedure

Use recommended weight, observe stable conditions, warm-up time, follow key presses.

Adjustment Procedure Steps

Switch on, press/hold CAL, wait for signal, place weight, press SET/M.

Operation

Display Overview

Illustrates display and buttons for CB and FCB model series.

Weighing Operation

Switch on, ensure zero, place goods, read weight unit.

Taring Procedure

Place tare vessel, press TARE to zero display; repeatable for mixtures.

PRE-Tare Function

Stores tare weight, saved after power off; can be deleted.

Plus/Minus Weighing

Unit control; displays deviation from nominal weight with +/- signs.

Parts Counting

Set reference quantity, place pieces, balance counts units; accuracy increases with reference.

Net-Total Weighing

Weighs/sums components in tare vessel for total net weight.

Percent Weighing

Displays weight in percent relative to reference weight; set 100% by placing reference item.

Weighing Units Selection

Select units (g, lb, oz) or set freely selectable factor.

Display Background Illumination

Switch illumination on, off, or auto-off for contrast or battery saving.

Animal Weighing Function

Finds average weighing value over time; useful for moving subjects like animals.

Reset to Factory Settings

Resets all balance settings to default factory configuration; choose 'yes' or 'no'.

Settings Configuration

Menu Structure Overview

Diagram showing how to navigate the balance's menu for various settings.

Exiting Menu Structure

Save or reject changes; options to exit and save or exit without saving.

Dosing and Zero-Tracking

Auto-Zero tares small variations; Zero-Tracking can be activated/deactivated.

Adjustment Weight Selection

Select adjustment weight from preset values (1/3, 2/3, max) for optimal results.

RS232C Interface Configuration

Data Transfer Mode Settings

Set data transfer mode (e.g., Pr PC, AU Pr) for peripheral communication.

Baud Rate Settings

Set baud rate (e.g., 9600) for data transmission between balance and peripheral.

Print Output Selection

Select data (headlines, net weight, units) sent via RS232C interface.

RS 232 C Data Output

RS 232 C Technical Data

Details on ASCII code, bits, parity, and baud rates for RS232C.

RS 232 C Output Socket Pin Allocation

Diagram showing pin assignment for transmit data, receive data, and signal ground.

Data Transfer Formats

Explains data formats for weight/quantity/percentage and fault cases.

AU PC Data Transfer Format

Details data formats for AU PC mode, including stable, fault, and unstable values.

RE Cr Command Explanation

Explains remote commands (s, w, t) for weight data and tare function.

RE Cr Data Transfer Formats

Details data formats for RE Cr mode, including stable, fault, and unstable values.

Barcode Printer Output

Configure mode for Zebra printer; fixed format, print label with PRINT key.

Service, Maintenance, and Disposal

Cleaning Instructions

Use mild soap suds; avoid aggressive agents and liquid penetration; clean residue carefully.

Service and Maintenance

Only authorized technicians may open; disconnect power first.

Disposal Guidelines

Dispose of packaging and appliance according to valid national or regional laws.