Operation / emptying
37 / 48V 1.0
4.1 Emptying system type A
• Open inspection cover.
• Empty system tank (extraction).
• When the system tank is about 1 third empty, open the hot water inlet.
• When the system tank is completely empty, remove the extraction hose from the disposal vehicle and switch
the hot water supply off.
• Clean the system tank (spray out).
If the system tank is not lled with water again after emptying (level of tank overow), greases and suspended
matter can ow freely into the sewage system.
• Fill the system tank up to the system overow.
• Seal the inspection cover.
4.2 Emptying system type B
• Open inspection cover.
• Connect the extraction hose of the disposal vehicle to the direct disposal pipe.
• Empty system tank (extraction).
• When the system tank is about 1 third empty, open the hot water inlet.
• When the system tank is completely empty, remove the extraction hose from the disposal vehicle and switch
the hot water supply off.
• Clean the system tank (spray out).
If the system tank is not lled with water again after emptying (level of tank overow), greases and suspended
matter can ow freely into the sewage system.
• Fill the system tank up to the system overow.
• Seal the inspection cover.