Operation / emptying
37 / 48V 1.0
4.1 Emptying system type A
• Open inspection cover.
• Empty system tank (extraction).
• When the system tank is about 1 third empty, open the hot water inlet.
• When the system tank is completely empty, remove the extraction hose from the disposal vehicle and switch
the hot water supply off.
• Clean the system tank (spray out).
If the system tank is not lled with water again after emptying (level of tank overow), greases and suspended
matter can ow freely into the sewage system.
• Fill the system tank up to the system overow.
• Seal the inspection cover.
4.2 Emptying system type B
• Open inspection cover.
• Connect the extraction hose of the disposal vehicle to the direct disposal pipe.
• Empty system tank (extraction).
• When the system tank is about 1 third empty, open the hot water inlet.
• When the system tank is completely empty, remove the extraction hose from the disposal vehicle and switch
the hot water supply off.
• Clean the system tank (spray out).
If the system tank is not lled with water again after emptying (level of tank overow), greases and suspended
matter can ow freely into the sewage system.
• Fill the system tank up to the system overow.
• Seal the inspection cover.