Do you have a question about the Keyence IG Series and is the answer not in the manual?
Protection Rating | IP67 |
---|---|
Type | Laser Displacement Sensor |
Light Source | Semiconductor laser |
Output | Analog voltage output, Analog current output |
Measurement Principle | Triangulation |
Laser Type | Class 2 (IEC/EN 60825-1) |
Power Supply | 12 to 24 VDC |
Operating Temperature | 0°C to 50°C |
Introduction to the multi-purpose CCD laser micrometer, IG Series, highlighting its capabilities.
Highlights wide application modes for easy, high-accuracy measurements.
Focuses on the high stability of the digital laser sensor due to its technology.
Details repeatability of 5 µm and linearity of ±0.1% for the IG-028 model.
Lists common application modes like edge control and diameter measurement.
Specifies the maximum measurement distances for IG-028 and IG-010 models.
Explains the L-CCD element for stable target measurement and environmental insensitivity.
Details the enclosure's resistance to harsh environments and long-term durability.
Describes panel mount and DIN-rail mount display units for data output.
Details the Intelligent, Rugged, and Easy aspects of the IG Series sensors.
Explains the advanced optical system for high stability and accuracy.
Describes the sensor's ability to detect transparent and mesh targets stably.
Position monitor aids in visually checking target detection and preventing errors.
Position monitor facilitates easy optical axis alignment for optimal performance.
Explains how the L-CCD sensor is less sensitive to dirt, simplifying maintenance.
Features a durable cable designed for repeated motion and bending.
Allows users to verify correct measurement by checking edge counts.
Details three primary application modes: Edge Control, Outer Diameter, and Inner Diameter.
Explains specialized mode for detecting edges of transparent objects.
Shows feedback and positioning control using edge data and output signals.
Demonstrates positioning and edge control for glass substrates.
Explains real-time detection of abnormal diameters and deformations.
Details controlling product thickness by measuring gaps between rollers.
Discusses the IG Configurator software for settings and monitoring.
Features real-time waveform monitoring and precise sensitivity adjustments.
Explains addition/subtraction calculations and the zero shift function.
Details NPN/PNP output selection, bank function for settings, and analog output options.
Lists various communication units for network integration.
Presents sensor heads, display units, and accessory cables.
Lists optional items like PC software, mounting brackets, and cables.
Provides detailed technical specifications for IG-010 and IG-028 sensor heads.
Covers amplifier types, power, display methods, and resolution for all models.
Details output types, input functions, and environmental resistance for display units.
Provides detailed dimensional drawings for IG-010 and IG-028 sensor heads.
Shows dimensions for sensor head mounting brackets.
Presents dimensional diagrams for DIN rail and panel mount amplifier units.
Illustrates the wiring diagram for amplifier units and their connections.
Details specifications for EtherCAT, PROFINET, PROFIBUS, EtherNet/IP, DeviceNet, CC-Link, TCP/IP, RS-232C, and BCD units.
Provides dimensional drawings for the various communication units.